Program Parameterization AsComm manual
10 October 2007 ©ASKOM, Gliwice
uses it (asix), has ended its work.
The AsComm program will not be closed
too when during its operation it was used in
not minimized form.
Allowable values: Yes, No
Log Specifies a file name, to which diagnostic
information will be written
N/A
Parameters determining the way of access to resource
Parameters determining the way of access to resource are placed in a section of the same
name as the client name:
Name Description Default
value
Baud Transmission speed 9600
stop_bits Number of stop bits 1
Com Number of serial port N/A
Disconnection_Time Time of terminating a connection 500 ms
Word_Length Word length 8
Accuracy Accuracy of determining a connection
beginning
5000ms
Interval Time period of establishing connections
for cyclic connections. A new connection
is established when the time, which passed
from the termination of previous
connection, is longer than the time
specified by parameter Interval.
N/A
Switched_Line Determines if a modem connection is used.
Allowable values: Yes, No
No
Max_Connection_Time Determines the maximal duration time of
connection.
If the parameter Max_Connection_Time is
given for the resource too then the smaller
one of given values is taken into
consideration.
N/A
Min_Inter_Connection_Time Minimal time interval between
connections. If the parameter
Min_Connection_Time is given for the
resource too then the greater one of given
values is taken into consideration.
0
Min_Connection_Time Minimal duration time of connection. The
parameter permits to determine the
minimal duration time of connection
required by the client. If many clients use
the established connection, the parameter
Max_Connection_Time is specified and the
remaining time to connection termination
is shorter than it is determined by the
parameter Min_Connection_Time then the
client does not receive the allocation
N/A
Modem Modem name if a modem connection is
used for connections. It is
ossible to
ive
N/A