(b) Input PC2 IP 192.168.4.33.
(c) Enable all plug-in with default settings (Even dangerous plug-in are enabled).
(d) Scan from the local host.
(e) Scan Now.
(3) When scan finished, ZyWALL will hung.
(4) Another easier way to reproduce the hang is that send the attached packet by
Sniffer.
27. [BUG FIX] SPR ID: 071120328
Symptom: Log for connectivity check fail Source IP and Destination IP should be
NULL when domain name doesn't exist. Shouldn't show the Destination IP of the last
time ping.
Condition:
(1) Goto eWC>Network>WAN>General.
(2) Enable” Check WAN1 Connectivity, and let system PING 1.1.1.1 this IP.
(3) Log show ping check fail, Source IP= WAN IP, Destination IP=1.1.1.1
(4) Enable "Check WAN1 Connectivity" and let system PING
"www.abcdefg123aabbccdd.com" which doesn't exist.
(5) There is log for ping check fail, but, Source IP =WAN IP, Destination IP=1.1.1.1,
so, log is incorrect. If your domain inexistent, Source IP and Destination IP should
equal to NULL.
28. [BUG FIX] SPR ID: 071120338
Symptom: The static DHCP rule cannot be saved under special condition.
Condition:
(1) Add a static DHCP rule at the end of the DHCP table.
(2) Add the same MAC address with different IP address before the end rule, it shows
"Duplicate MAC Address" message.
(3) Delete the end rule added in step 1.
(4) Add other different MAC address rule, and then apply. It can't be saved with the
message "Duplicate MAC Address".
29. [BUG FIX]
Fixed the DDNS service provider FQDN as follows:
WWW.DynDNS.ORG => WWW.DynDNS.COM
30. [BUG FIX] SPR ID: 080114603
Symptom: ZyWALL can't send allowed CF log to report server
Topology:
PC----(lan)ZyWALL(wan)----report server
Condition:
(1) Register CF service on alpha.myzyxel.com
(2) Configure CF log server address using CLI command
Seitenansicht 14