ZyXEL Communications U-1496 series Spezifikationen Seite 15

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 14
INSTALLATION AE/LZB 119 1889 R1A
15
To change the amount of time between each step in the
sequence, type setmiscP,displayOffTimeLX (replacing
X with the desired amount of time in milliseconds), and
press the Enter key (default is 500).
Bottom Line of Display
The bottom line of the SIM display is used to show the
messages shown in Table 3. To change the amount of time
each message is displayed if it is not replaced by another
message, type setmiscP,displayPersistanceLZ (replace
Z with the time in milliseconds), and press the Enter key
(default is 5000). Note that when two or more activities
occur in rapid succession, the messages may not be
displayed for the full amount of time.
To save the programming for the SIM display, do the
following:
1. Type runmiscP,verifyAndLoad() and press
the Enter key. The SIM should respond by
displaying the word OK.
2. Type runPersonalityObject,programFlash()
and press the Enter key. The SIM should respond
by displaying the word OK.
Station GETC Communications
The default baud rate for BSL communications between
all GETCs and the SIM is 38,400 bps. If a “BSL Fail”
message is seen on the SIM display, the baud rates may not
be the same. To make sure that the BSL baud rate is set to
38,400 bps in the SIM, use the following procedure:
1. Press Ctrl + E to get the SIM to echo the typed
characters, so that you will be able to see (on the
screen of the PC or terminal) what you type.
2. Type setsiteP,highSpeedBSLB1 and press the
Enter key.
3. Type runsiteP,verifyAndLoad() and press
the Enter Key.
4. Type
runPersonalityObject,programFlash() and
press the Enter key.
5. Reset the SIM (push button in hole in front panel).
If it is necessary to set the BSL baud rate to 19,200 bps
in the SIM, use the same procedure but change step 2 as
follows:
2. Type setsiteP,highSpeedBSLB0 and press the
Enter key.
When programming of the SIM is complete, disconnect
the programming cable from the SIM.
Table 3 - Messages for Bottom Line of Display
MESSAGE DESCRIPTION
BSL Fail No polling message has been received
by the SIM from the Control Channel
GETC for 15 seconds.
SMDisct The System Manager interface is
disconnected. If this message appears
every 15 to 30 seconds, the System
Manager cannot be contacted and
something must be wrong with the
System Manager connection.
GIDUpLod The System Manager has started a GID
upload to the site.
GID Done The GID upload to the site is complete.
MONMorse Morse Code ID was transmitted.
MONGrpCA Group Channel Assignment.
MONDtGCA Data Group Channel Assignment
MONDtICA Data Individual Channel Assignment
MONSpcCA Special Channel Assignment
MONIndCA Individual Channel Assignment
MONSyACA System All Call Channel Assignment
MONLgnAk Login Acknowledge
MONStsAk Status Ack
MONSysId System Id message
MONUnkey Radio Unkey
MONCanDR Cancel Dynamic Regroup
MONIniTC Initiate Test call
MONStatus Status Message
MONWCSID Working Channel System Assigned ID
MONLogin Radio Login
MONPage Paging channel assignment
MONConGC Confirmed Group Channel Assignment
MONConIC Confirmed Indiv Channel Assignment
MONCTISG Central Interconnect Group Channel
Assignment
MONSDrop Short Drop
MONCConf Channel confirmed
MONWCKey Working channel Key
MONWCUKy Working Channel unkey
MONWCDrp Working Channel drop
MONDpCar Drop with carrier