E/LZB 119 1889 R1A INTERCONNECTION DIAGRAMS
Interconnection Diagram
Enhanced SCAT Site (AC Powered)
30
SERIAL MODULE
Downlink GETC
J14
J102
TB10
EDACS Interface Panel
SIM
J1
J2
DWNLINK DATA
J1
J14
X4
ZyXEL Modem
Equipment Cabinet - Enhanced SCAT Site (AC Powered)
SIM Modem Shelf
J13
J12
J9
J8
J7
SCAT GETC
X10
X14
AC
TB10
J102 J10
Power
Strip
MASTR III Repeater
J801
DC
AC
Power
Supply
F801B
SCAT EDACS Repeater
Power Cable
PA
P102
Phone Cable
RS-232 Cable
20V
with 20V Transformer
Xfmr
Leased Line
DTE/EIA-232D
Power Jack
DC AC
DC Power Supply
(Comes with Modem)
Power Cable
(Part of Power Supply)
SIM Power Cable
RPM 113 2512
(Customer Supplied)
No Connection
No Connection
SIM Modem Cable
RPM 113 2485
(Customer Supplied)
J4
To PC or Terminal
Programming Cable
RPM 113 2514
(Customer Supplied)
to
CEC / IMC Switch
Downlink
to
Remote System Manager
Local System Manager
to
or
Audio Data Link
DC Data Link
(Over 50 Feet)
(Within 50 Feet)
Kommentare zu diesen Handbüchern