Chapter 37 DHCP
GS3700/XGS3700 Series User’s Guide
304
37.4.4 DHCPv4 Global Relay Port Configure
Use this screen to apply a different DHCP option 82 profile to certain ports on the Switch. To open
this screen, click IP Application > DHCP > DHCPv4 > Global > Port.
Figure 192 IP Application > DHCP > DHCPv4 > Global > Port
The following table describes the labels in this screen.
Option 82
Profile
Select a pre-defined DHCPv4 option 82 profile that the Switch applies to all ports. The
Switch adds the Circuit ID sub-option and/or Remote ID sub-option specified in the profile to
DHCP requests that it relays to a DHCP server.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Cancel Click Cancel to begin configuring this screen afresh.
Table 155 IP Application > DHCP > DHCPv4 > Global (continued)
LABEL DESCRIPTION
Table 156 IP Application > DHCP > DHCPv4 > Global > Port
LABEL DESCRIPTION
Port Enter the number of port(s) to which you want to apply the specified DHCP option 82
profile.
You can enter multiple ports separated by (no space) comma (,) or hyphen (-). For
example, enter “3-5” for ports 3, 4, and 5. Enter “3,5,7” for ports 3, 5, and 7.
Option 82 Profile Select a pre-defined DHCP option 82 profile that the Switch applies to the specified
port(s). The Switch adds the Circuit ID sub-option and/or Remote ID sub-option
specified in the profile to DHCP requests that it relays to a DHCP server.
Note: The profile you select here has priority over the one you select in the DHCP >
DHCPv4 > Global screen.
Add Click this to create a new entry or to update an existing one.
This saves your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation
panel to save your changes to the non-volatile memory when you are done configuring.
Cancel Click this to reset the values above based on the last selected entry or, if not applicable,
to clear the fields above.
Clear Click Clear to reset the fields to the factory defaults.