Chapter 10 System Information
IES-1248-51V User’s Guide
100
The following table describes the labels in these screens.
Table 12 System Info
LABEL DESCRIPTION
External Alarm
Status
Name
Apply
The IES-1248-51V is able to detect alarm input from other equipment
connected to the ALARM connector.
The Status column displays Normal when no alarm input has been
detected from other equipment. It displays Abnormal when alarm
input has been detected from other equipment.
Use the Name column to configure a title for each external alarm for
identification purposes. Use up to 31 characters.
Click Apply to save the name changes to the IES-1248-51V’s volatile
memory. The IES-1248-51V loses these changes if it is turned off or
loses power, so use the Config Save link on the navigation panel to
save your changes to the non-volatile memory when you are done
configuring.
External Relay
Status
The IES-1248-51V is able to send alarm output to another piece of
equipment connected to the ALARM connector.
The Status column displays Normal when the IES-1248-51V is not
sending alarm output to another piece of equipment. It displays
Abnormal when the IES-1248-51V is sending alarm output to
another piece of equipment.
Fan Trap Mode Select the device’s fan trap mode.
Use this section of the screen to configure the hardware monitor
threshold settings.
New threshold
Apply
Configure new threshold settings in the fields below and click Apply
to use them.
Index This field is a sequential value.
Temperature (Hi) Use these fields to configure the highest temperature limit at each
sensor.
Temperature (Lo) Use these fields to configure the lowest temperature limit at each
sensor.
Volt. (Hi) Use these fields to configure the highest voltage limit at each sensor.
Volt. (Lo) Use these fields to configure the lowest voltage limit at each sensor.
Fan (Hi) Use these fields to configure the highest RPM limit at each sensor.
Fan (Low) Use these fields to configure the lowest RPM limit at each sensor.
Poll Interval(s)
Set Interval
The text box displays how often (in seconds) this screen refreshes.
You may change the refresh interval by typing a new number in the
text box and then clicking Set Interval.
Stop Click Stop to halt statistic polling.