Chapter 2 Hardware Installation
IES-1248-51V User’s Guide
50
2.3.2 Rack-Mounted Installation
2.3.2.1 Rack-mounted Installation Requirements
The IES-1248-51V can be mounted on an EIA standard size, 21-inch rack or in a
wiring closet with other equipment. Follow the steps below to mount your IES-
1248-51V on a standard EIA rack using a rack-mounting kit.
Make sure the rack will safely support the combined weight of all
the equipment it contains.
Make sure the position of the IES-1248-51V does not make the rack
unstable or top-heavy. Take all necessary precautions to anchor
the rack securely before installing the unit.
Use a #2 Phillips screwdriver to install the screws.
See Chapter 71 on page 579 for the gauge of wire to use for the frame ground
connections.
See Chapter 71 on page 579 for the hardware that is required to mount the IES-
1248-51V.
Failure to use the proper screws may damage the unit.
Do not block the ventilation holes. Leave space between IES-1248-
51V when stacking.
2.3.2.2 Rack-Mounted Installation Procedure
1 Align one bracket with the holes on one side of the IES-1248-51V and secure it
with the bracket screws smaller than the rack-mounting screws.